Title Accuracy of automatic and manual dynamic navigation registration techniques for dental implant surgery in posterior sites missing a single tooth: A retrospective clinical analysis
Authors Wu, Bin-Zhang
Xue, Fei
Ma, Yu
Sun, Feng
Affiliation Peking Univ, Sch & Hosp Stomatol, Clin Div 1, Beijing, Peoples R China
Natl Ctr Stomatol, Beijing, Peoples R China
Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
Natl Engn Res Ctr Oral Biomat & Digital Med Device, Beijing, Peoples R China
Peking Univ, Sch & Hosp Stomatol, Clin Div 1, 37A Xishiku St, Beijing 100034, Peoples R China
Keywords SURGICAL NAVIGATION
PLACEMENT
SYSTEM
SPLINT
BONE
Issue Date Feb-2023
Publisher CLINICAL ORAL IMPLANTS RESEARCH
Abstract ObjectivesTo assess the relative accuracy of manual (U-shaped tube) and automatic (two-in-one) dynamic navigation registration techniques for implant surgery performed in posterior sites missing one tooth. Materials and MethodsThis study included 58 partially edentulous patients with 58 implants, including 31 and 27 in the manual and automatic groups. Deviations between the planned and actual implant placement were assessed. ResultsThe angular deviation in the overall study cohort was 2.54 +/- 1.21 degrees, while the 3D deviations at the implant platform and apex were 0.90 +/- 0.46 mm and 1.04 +/- 0.47 mm, respectively. The respective angular deviations in the manual and automatic groups were 2.82 +/- 1.17 degrees and 2.21 +/- 1.19 degrees (p > .05), while platform deviations were 0.89 +/- 0.48 mm and 0.91 +/- 0.45 mm (p > .05), and apex deviations were 0.99 +/- 0.48 mm and 1.11 +/- 0.46 mm (p > .05). No significant differences in absolute buccolingual, mesiodistal, or apicocoronal deviations were detected between these groups at either level (p > .05) nor were did deviation distributions differ in the buccolingual, mesiodistal, or apicocoronal directions at the platform or apex levels (p > .05). ConclusionsManual and automatic dynamic navigation registration techniques can achieve excellent accuracy when placing implants in posterior sites missing a single tooth. The two-in-one automatic registration technique can reduce the amount of time and intraoperative steps necessary to complete the registration process relative to the manual U-shaped tube registration technique. Further follow-up studies are necessary to expand on these results.
URI http://hdl.handle.net/20.500.11897/671222
ISSN 0905-7161
DOI 10.1111/clr.14034
Indexed SCI(E)
Appears in Collections: 口腔医院

Files in This Work
There are no files associated with this item.

Web of Science®


0

Checked on Last Week

Scopus®



Checked on Current Time

百度学术™


0

Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.