Title Comparison of the accuracy of two different dynamic navigation system registration methods for dental implant placement: A retrospective study
Authors Ma, Feifei
Sun, Feng
Wei, Tai
Ma, Yu
Affiliation Peking Univ, Clin Div 1, Sch & Hosp Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Natl Ctr Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Natl Clin Res Ctr Oral Dis, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Natl Engn Lab Digital & Mat Technol Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Beijing Key Lab Digital Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Minist Hlth, Res Ctr Engn & Technol Computerized Dent, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
NMPA Key Lab Dent Mat, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Keywords SURFACE REGISTRATION
PATIENT REGISTRATION
SURGERY
RECONSTRUCTION
TECHNOLOGY
Issue Date May-2022
Publisher CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH
Abstract Background Dynamic navigation approaches are widely employed in the context of implant placement surgery, with registration being integral to the accuracy of such navigation. Relatively few studies to date, however, have compared different registration approaches, and such a comparison has the potential to guide the development of more accurate and reliable clinical registration methodology. Purpose This study was developed to compare the accuracy of dynamic navigation-based dental implant placement conducted using either U-tube or cusp registration methods. Materials and Methods Medical records from all patients that had undergone implant surgery between August 2019 and October 2020 in the First Clinical Division of the Peking University Hospital of Stomatology were retrospectively reviewed, with 64 patients and 99 implants ultimately meeting with study inclusion criteria. Implant placement accuracy was gauged via the superimposition of the planned implant position in preoperative cone-beam computed tomography (CBCT) images with the true postoperative implant position in postoperative CBCT images. Accuracy was measured based upon the angular deviation, entry deviation (3-dimensional [3D] deviation in the coronal aspect of the alveolar ridge), and apex deviation (3D deviation in the apical area of the implant) when comparing these two positions. Results The angular deviation, entry deviation, and apex deviation of all analyzed implants were 3.29 +/- 0.17 degrees, 1.29 +/- 0.07 mm, and 1.43 +/- 0.08 mm, respectively, while in the cusp registration group these respective values were 3.25 +/- 1.58 degrees, 1.28 +/- 0.60 mm, and 1.34 +/- 0.63 mm as compared to 3.35 +/- 1.78 degrees, 1.30 +/- 0.78 mm, 1.55 +/- 0.9 mm in the U-tube group, respectively. No significant differences in accuracy were observed when comparing these two registration techniques. Conclusion Dynamic computer-assisted surgical systems can facilitate accurate implantation, and both the U-tube and cusp registration methods exhibit similar levels of accuracy. As the cusp registration technique can overcome some of the limitations of the U-tube strategy without the need for an additional registration device, it may be more convenient for clinical use and warrants further research.
URI http://hdl.handle.net/20.500.11897/643233
ISSN 1523-0899
DOI 10.1111/cid.13090
Indexed SCI(E)
Appears in Collections: 口腔医院

Files in This Work
There are no files associated with this item.

Web of Science®


0

Checked on Last Week

Scopus®



Checked on Current Time

百度学术™


0

Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.