Title Evaluation of the accuracy of computer-assisted techniques in the interstitial brachytherapy of the deep regions of the head and neck
Authors Zhang, Guo-Hao
Lv, Xiao-Ming
Wu, Wen-Jie
Wu, Zhi-Yuan
Zheng, Lei
Huang, Ming-Wei
Wang, Yong
Zhang, Jian-Guo
Affiliation Peking Univ, Dept Oral & Maxillofacial Surg, Sch & Hosp Stomatol, 22 Zhongguancun South Ave, Beijing 100081, Peoples R China
Peking Univ, Natl Engn Lab Digital & Mat Technol Stomatol, Res Ctr Engn & Technol Digital Dent,Minist Hlth, Ctr Digital Dent,Sch & Hosp Stomatol,Beijing Key, Beijing, Peoples R China
Keywords Computer-assisted technique
Individual template
Navigation
Brachytherapy
Accuracy
Head
Neck
Issue Date 2019
Publisher BRACHYTHERAPY
Abstract PURPOSE: We sought to investigate the feasibility and accuracy of computer-assisted techniques in the interstitial brachytherapy of the deep regions of the head and neck. MATERIALS AND METHODS: A computer-assisted brachytherapy workflow was applied to 10 patients with tumors in the deep regions of the head and neck. Based on the brachytherapy treatment preplan, we constructed a digital stereotactic model to accurately transfer the virtual plan into the navigation system, and subsequently printed the individual templates. The navigation system and the individual template were combined together to visualize and guide brachytherapy needle implantation. Preoperative and intraoperative image data were reconstructed and registered to measure and analyze the needle deviation. RESULTS: A total of 58 needles were successfully inserted in 10 patients with the guidance of computer-assisted techniques and a mean deviation of 5.2 mm. The inserting trajectories and depths of the needles were as follows: from the parotid and masseter regions to the infratemporal fossa or skull base, the range was 15.7-74.6 mm; from the submandibular and retromandibular regions to the infratemporal fossa or skull base, the range was 15.6-70.6 mm; from the infraorbital region to the pterygomandibular region, the range was 63.7-69.7 mm; and from the periorbital region to the intraorbital region, the range was 47.6-61.8 mm. The dose distribution met the treatment requirement well. CONCLUSIONS: The computer-assisted interstitial brachytherapy workflow was proven to be feasible and accurate for the deep regions of the head and neck. (C) 2018 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
URI http://hdl.handle.net/20.500.11897/544223
ISSN 1538-4721
DOI 10.1016/j.brachy.2018.12.003
Indexed CPCI-S(ISTP)
SCI(E)
Appears in Collections: 口腔医院

Files in This Work
There are no files associated with this item.

Web of Science®


0

Checked on Last Week

Scopus®



Checked on Current Time

百度学术™


0

Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.