TitleCompressed sensing based simultaneous black- and gray-blood carotid vessel wall MR imaging
AuthorsLi, Bo
Li, Hao
Kong, Hanjing
Dong, Li
Zhang, Jue
Fang, Jing
AffiliationFirst Hosp Nanchang City, Ctr Lab, Nanchang 330008, Jiangxi, Peoples R China.
Nanchang Univ, Affiliated Hosp 3, Dept Radiol, Nanchang 330008, Jiangxi, Peoples R China.
Univ Cambridge, Dept Radiol, Cambridge CB2 0QQ, England.
Peking Univ, Acad Adv Interdisciplinary Studies, Beijing 100871, Peoples R China.
Capital Med Univ, Beijing Anzhen Hosp, Dept Radiol, Beijing 100029, Peoples R China.
Peking Univ, Coll Engn, Beijing 100871, Peoples R China.
KeywordsCompressed sensing
Simultaneous three dimensional dual-contrast imaging
Gray-blood imaging
CS-siBLAG
Pseudo-centric phase encoding order
Vessel wall imaging
ATHEROSCLEROTIC PLAQUE COMPONENTS
STATE FREE PRECESSION
MAGNETIC-RESONANCE
INVERSION-RECOVERY
INITIAL-EXPERIENCE
VULNERABLE PLAQUE
RECONSTRUCTION
RELAXATION
SEQUENCE
CORONARY
Issue Date2017
PublisherMAGNETIC RESONANCE IMAGING
CitationMAGNETIC RESONANCE IMAGING.2017,38,214-223.
AbstractObjective: In this study, we sought to demonstrate the blood suppression performance, image quality and morphological measurements for compressed sensing (CS) based simultaneous 3D black- and gray-blood imaging sequence (CS-siBLAG) in carotid vessel wall MR imaging. Materials and methods: Seven healthy volunteers and five patients were recruited. Healthy subjects underwent five CS-siBLAG scans with 1, 2, 3, 4 and 5-fold accelerations. Signal-to-tissue ratio (STR) and contrast-to-tissue ratio (CTR) were computed as the measures of flowing signal suppression performance and the image quality for black-blood imaging of the technique. Vessel lumen area (LA) and wall area (WA) were compared between fully sampled acquisition and each accelerated acquisition. Patients underwent three CS-siBLAG scans with 1, 3 and 5-fold accelerations as well as a 3D time of flight (3D TOF) scan. Two radiologists reviewed the under-sampled black- and gray-blood image quality. Results: STR and CTR values obtained with 2 to 5-fold accelerations were not significantly different from those with full acquisition. LA and WA measured at 2 x, 3 x, 4x and 5 x were all highly correlated to the corresponding values at 1 x. For patients imaging, two radiologists both found that the dual-contrast images at 3 x acceleration exhibited comparable image quality to that of the fully sampled acquisition, and that the images at 5 x exhibited slightly blurred vessel wall and outer vessel wall boundaries. Conclusion: By combining the CS under-sampling pattern and reconstruction, pseudo-centric phase encoding order and dual blood contrast sequences, this technique provides spatially registered black- and gray-blood images and excellent visualization for vessel wall imaging and gray-blood imaging in a short scan time. (C) 2017 Elsevier Inc. All rights reserved.
URIhttp://hdl.handle.net/20.500.11897/473848
ISSN0730-725X
DOI10.1016/j.mri.2017.01.013
IndexedSCI(E)
Appears in Collections:前沿交叉学科研究院
工学院

Files in This Work
There are no files associated with this item.

Web of Science®



Checked on Last Week

Scopus®



Checked on Current Time

百度学术™



Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.