Title Development of RE1/1 RPCs for the CMS muon trigger system
Authors Park, S.
Ahn, S.H.
Akimenko, S.
Anan, P.S.
Bahk, S.Y.
Ban, Y.
Cai, J.
Cho, S.W.
Crotty, I.
Ge, Y.C.
Hong, B.
Hong, S.J.
Iaselli, G.
Ito, M.
Jonalegedda, S.
Kang, T.I.
Kim, B.I.
Kim, H.C.
Kim, J.H.
Kim, T.J.
Kim, Y.J.
Kim, Y.U.
Koo, D.G.
Kuo, R.
Lee, H.S.
Lee, K.B.
Lee, K.S.
Lee, S.J.
Lim, J.K.
Liu, H.
Marinov, A.
Nam, S.K.
Qian, S.J.
Rhee, H.B.
Rhee, J.T.
Ryu, M.S.
Sharma, A.
Sim, K.S.
Van Doninck, W.
Xue, Z.H.
Affiliation Department of Physics, Korea Detector Laboratory, Korea University, Seoul, Korea, Republic of
Neuralscience Research Institute, Gachon Medical School, Incheon, Korea, Republic of
Department of Physics, Wonkwang University, Iksan, Korea, Republic of
Department of Physics, Cheju National University, Cheju, Korea, Republic of
Department of Physics, Chungbuk National University, Chungjoo, Korea, Republic of
Department of Physics, Seoul National University of Education, Seoul, Korea, Republic of
Department of Biomedical Engineering, Seonam University, Namwon, Korea, Republic of
Department of Physics, Kangwon National University, Chunchon, Korea, Republic of
Institute for Advanced Physics, Konkuk University, Seoul, Korea, Republic of
School of Physics, Peking University, Peking, China
CERN, Geneva, Switzerland
Vrije Universiteit Brussels, Brussels, Belgium
IHEP, Protvino, Russia
University of Sophia, Sophia, Bulgaria
INFN, Bari, Italy
Issue Date 2009
Publisher Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Citation Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.2009,602(3),665-667.
Abstract The first six Resistive Plate Chambers (RPCs) of RE1/1 in the forward region of the Compact Muon Solenoid (CMS) detector were constructed and are being tested. These RPCs cover the pseudo-rapidity region from 1.6 to 2.1 and will serve as the base detector for the CMS RPC muon trigger. We report that these six RPCs are being tested with the CMS RPC quality certification procedures and that a full measurement of a chamber efficiency of 95 ?? 4 % has been achieved at an operating voltage of 9.4 kV. This performance demonstrates that the RPC is qualified to be tested at the closest distance to the beam pipe as the muon trigger detector at the full LHC design luminosity. ? 2008 Elsevier B.V. All rights reserved.
URI http://hdl.handle.net/20.500.11897/460945
ISSN 01689002
DOI 10.1016/j.nima.2008.12.073
Indexed EI
Appears in Collections: 物理学院

Files in This Work
There are no files associated with this item.

Web of Science®


0

Checked on Last Week

Scopus®



Checked on Current Time

百度学术™


0

Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.