Title3D Algebraic Iterative Reconstruction for Cone-Beam X-Ray Differential Phase-Contrast Computed Tomography
AuthorsFu, Jian
Hu, Xinhua
Velroyen, Astrid
Bech, Martin
Jiang, Ming
Pfeiffer, Franz
AffiliationBeijing Univ Aeronaut & Astronaut, Res Ctr Digital Radiat Imaging & Biomed Imaging, Beijing 100191, Peoples R China.
Tech Univ Munich, Dept Phys, Lehrstuhl Biomed Phys, D-85748 Garching, Germany.
Tech Univ Munich, Inst Med Tech, D-85748 Garching, Germany.
Lund Univ, S-22185 Lund, Sweden.
Peking Univ, Sch Math Sci, Beijing 100871, Peoples R China.
KeywordsIMAGE-RECONSTRUCTION
GRATING INTERFEROMETER
SYNCHROTRON-RADIATION
ALGORITHMS
TOPOGRAPHY
FORMULA
CT
Issue Date2015
Publisherplos one
CitationPLOS ONE.2015,10,(3).
AbstractDue to the potential of compact imaging systems with magnified spatial resolution and contrast, cone-beam x-ray differential phase-contrast computed tomography (DPC-CT) has attracted significant interest. The current proposed FDK reconstruction algorithm with the Hilbert imaginary filter will induce severe cone-beam artifacts when the cone-beam angle becomes large. In this paper, we propose an algebraic iterative reconstruction (AIR) method for cone-beam DPC-CT and report its experiment results. This approach considers the reconstruction process as the optimization of a discrete representation of the object function to satisfy a system of equations that describes the cone-beam DPC-CT imaging modality. Unlike the conventional iterative algorithms for absorption-based CT, it involves the derivative operation to the forward projections of the reconstructed intermediate image to take into account the differential nature of the DPC projections. This method is based on the algebraic reconstruction technique, reconstructs the image ray by ray, and is expected to provide better derivative estimates in iterations. This work comprises a numerical study of the algorithm and its experimental verification using a dataset measured with a three-grating interferometer and a mini-focus x-ray tube source. It is shown that the proposed method can reduce the cone-beam artifacts and performs better than FDK under large cone-beam angles. This algorithm is of interest for future cone-beam DPC-CT applications.
URIhttp://hdl.handle.net/20.500.11897/187746
ISSN1932-6203
DOI10.1371/journal.pone.0117502
IndexedSCI(E)
PubMed
Appears in Collections:数学科学学院

Web of Science®



Checked on Last Week

Scopus®



Checked on Current Time

百度学术™



Checked on Current Time

Google Scholar™





License: See PKU IR operational policies.